The short answer: Colorado State University (CSU) Extension says backflow prevention devices "must be installed on all sprinkler systems" that use drinking water, and where that device is a testable assembly (a pressure vacuum breaker or a reduced pressure assembly), a certified tester checks it on a schedule your water utility sets. Irrigation is where the backflow rules meet the calendar: you drain the system in fall and refill it in spring, sometimes with a new pump or injector. Each step touches the rules: which device you need, when the test is due, whether draining counts as a reason to retest, and whether a replacement needs a permit.
This guide takes them in order, naming the rule behind each answer. Salt Lake City names "lawn sprinkling systems" first among residential cross-connections. The field test itself is covered in how backflow testing works. Prices and utility fees are in the backflow testing cost guide.
Why a lawn sprinkler system counts as a hazard
A sprinkler head spends most of its life retracted into the soil of a lawn that gets fertilizer, weed killer and dog traffic. A brochure from the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC FCCCHR), whose field test procedures Oregon's rule names (or approved equivalents) and Washington's rule cites, says it in one line: "Water pooling around sprinkler heads may be contaminated by chemicals, fertilizers, or animal waste."
The trouble starts when pressure on the supply side drops. CSU Extension describes the chain: "Any drop in pressure in the main city water line can result in back-siphonage backflow of fertilizers, pesticides, manures and other contaminants through sprinkler heads and the irrigation piping system into the potable water supply." The causes it lists are ordinary ones, a break in the line or heavy withdrawal "as may occur during firefighting operations" (CSU Extension, Home Sprinkler Systems: Backflow Prevention Devices, reviewed August 2025).
The second path is backpressure. CSU warns that an improperly installed lawn sprinkler pump or injector "may force contaminants back into the potable water supply," because the pump pushes harder than the city main. That is why the device choice below depends on whether anything on your side can push.
The garden hose belongs in the same picture. CSU says a hose connection vacuum breaker "should be used as minimum protection when fertilizers, insecticides or other pesticides are applied with a hose-end sprayer." The U.S. EPA's Cross-Connection Control Manual includes both the "lawn sprinkler system" and the "weedicide and fertilizer sprayer" aspirator in its partial list of plumbing hazards.
How often are household connections left unprotected? The best survey we found is old and small. USC FCCCHR inspected 188 single-family homes in one Iowa water system between May 2002 and January 2003 under an EPA grant. Unprotected hose bibs turned up in 91% of homes, and 95.7% had a direct or indirect cross-connection to a health hazard. Only five of the homes had an irrigation system, and one of the five was unprotected. The authors added that irrigation systems, "which are common in some parts of the country, could easily contribute to the potential for backflow occurrences in residences" (USC FCCCHR, Prevalence of Cross-Connections in Household Plumbing; report dated February 3, 2004).
Show the numbers
| Item | Value | Note |
|---|---|---|
| Direct or indirect cross-connection to a health hazard | 95.7 % of homes | |
| Unprotected hose bibs | 91 % of homes | |
| Unprotected cross-connections involving toilets | 61 % of homes | |
| Heating/cooling system cross-connections | 43.6 % of homes | |
| Direct cross-connection to a health hazard | 9.6 % of homes | |
| Cross-connections to tanks, vats or water softeners | 5.9 % of homes |
Small, older sample: 188 mostly older single-family homes in one water system, not a national rate. Only 5 had an irrigation system; 1 of those 5 was unprotected. Hose bibs are where garden hoses and hose-end sprayers connect. Source: USC Foundation for Cross-Connection Control and Hydraulic Research, Prevalence of Cross-Connections in Household Plumbing Systems (report dated February 3, 2004), Summary of Results Table, accessed 2026-11-04.
Which backflow device an irrigation system needs
Four kinds of device show up on sprinkler lines. The atmospheric vacuum breaker (AVB) and the pressure vacuum breaker (PVB) protect only against backsiphonage. California's handbook says a PVB "is not to be used to protect from backpressure." The reduced pressure principle assembly (RP) protects against both backsiphonage and backpressure, and Salt Lake City rates it for health and non-health hazards. The double check (DC) also handles both directions, but California says it "may only be used to isolate low hazard cross-connections." Two questions decide which one your system gets. Can anything on your side push water backward: a pump, an injector, a second water source? And is anything added to the water that makes it a health hazard?
| Jurisdiction | Water-only lawn system | Chemicals added or injected | Pump, second water source or septic |
|---|---|---|---|
| Texas (30 TAC 344, landscape irrigation) | PVB or spill-resistant PVB if there is "no actual or potential for a back-pressure condition," installed at least 12 inches above downstream piping and the highest downstream opening. A DC only where there is no health hazard and the local authority does not prohibit it | RP or air gap "before any chemical is added by any method (aspiration, injection, etc.)" | Any additional water source: RP or air gap. A property with an on-site sewage facility: the system is a health hazard and needs an RP |
| Washington (WAC 246-290-490) | The purveyor "may accept an approved AVB on a residential irrigation system" installed under the plumbing code | "Premises with separate irrigation systems using the purveyor's water supply and with chemical addition" (parks, golf courses, cemeteries, estates) need an air gap or RP at the premises | "Premises with an unapproved auxiliary water supply interconnected with the potable water supply" are on the same air gap or RP list |
| Ohio (OAC 3745-95-05) | By exception, an approved PVB at the cross-connection to the irrigation system "may be used as the containment backflow preventer" for "a water-only, residential-type irrigation system that is not subjected to backpressure." The water supplier may require more | "This exception does not apply if an additive is used within the irrigation system" | The PVB exception is limited to systems "not equipped with pumps or other prime movers which can create backpressure" |
| California (Cross-Connection Control Policy Handbook) | PVB or SVB at least 12 inches above all downstream piping and outlets. A PVB may be premises containment only for roadway right-of-way irrigation | Not addressed separately for home irrigation | Homes irrigating with recycled water in an approved dual-plumbed area: at least a DC |
| Salt Lake City (utility installation specs) | AVB, PVB or RP. DC "no longer allowed" for lawn sprinkling systems, though an existing one may be kept if tested annually | Not addressed separately | RP where secondary (non-potable) water is available |
| Hastings, Minnesota (city irrigation permit packet) | PVB, at least 12 inches above the highest sprinkler head | "Systems equipped with a pump or capable of chemical injection" need an RP | Same rule: a pump means an RP |
| Colorado (CSU Extension guidance, not a rule) | PVB and RP are "the ones commonly used in residential sprinkler systems" | Injection "requires the use of a device such as the reduced pressure principle backflow assembly" | Dual systems carrying irrigation and potable water need an RP. Ditch-only systems need no backflow protection |
Sources: 30 TAC 344.50-344.51; WAC 246-290-490 Table 13; OAC 3745-95-05(D); California handbook 3.3.2 and Appendix D; Salt Lake City; Hastings; CSU Extension. Your utility can be stricter than its state.
Why an injector or a pump changes the answer
A PVB is one check valve plus an air inlet that opens when supply pressure falls. It can break a siphon. It cannot hold back water that is being pushed toward the main, which is exactly what a pump or a pressurized injector can do. Adding fertilizer also raises the stakes, because the water sitting in the pipes now carries the chemical. Both problems point to the same device. Texas requires an RP or an air gap once chemicals are involved, Hastings requires an RP, CSU's guidance names the RP, and Ohio withdraws its PVB option. Washington's air gap or RP list names premises with separate irrigation systems and chemical addition, such as parks and golf courses.
This is the change that catches homeowners: a PVB that passed for years no longer meets the Texas, Ohio or Hastings rules once an injector goes in. Texas puts the timing in the rule: the RP or air gap has to be in place "before any chemical is added." If you plan to add fertigation, a booster pump or a connection to a well or pond, ask your utility or permit office which device it wants before the work starts.
Height: why some yards get an RP without any chemicals
A PVB works by letting air into the line, so it has to sit above everything it protects. Texas, California and Hastings all require at least 12 inches above the highest downstream piping or sprinkler head, and Texas measures pop-up heads "from the retracted position from the top of the sprinkler" (30 TAC 344.50(b)(3)). On a sloped lot, the highest head may be above any spot where a PVB could go. CSU notes that RPs "are often used when pressure vacuum breakers cannot be used (i.e. when downstream piping is higher than the 12-inch clearance mentioned above)."
The AVB: a sprinkler device that usually is not tested
Some systems have an atmospheric vacuum breaker on each zone valve instead of one PVB at the supply. CSU describes it as gravity-operated and needed on each zone, and Salt Lake City's sheet says it must be installed 6 inches above the highest sprinkler head. Salt Lake City lists the AVB as "Not required to be tested annually." Washington has AVBs on irrigation systems inspected at installation, after a backflow incident and after repair, reinstallation or relocation, rather than tested yearly (WAC 246-290-490(7)(c)). If your notice names a testable assembly and you can only find AVBs on the zone valves, call the number on the notice before booking a tester.
How often the sprinkler device is tested
"Annual" is the common answer, but it is not universal, and irrigation is where the exceptions are. Texas' landscape irrigation rule requires a test "upon installation, repair, replacement, or relocation," and adds the annual test only for "irrigation systems designated as health hazards" (30 TAC 344.50(e)). Texas defines a health hazard as a situation involving any substance that "can cause death, illness, spread of disease" if it enters the drinking water supply (30 TAC 344.1). That leaves Texas cities room to set longer cycles for plain lawn systems, and some do.
| Rule or utility | Residential irrigation device | Timing detail |
|---|---|---|
| Texas, state rule | On installation, repair, replacement or relocation; annually if the system is a health hazard | The irrigator must have the assembly tested before it is placed in service and give results to the water purveyor within ten business days (344.52(c)) |
| Round Rock, TX | Once every 7 years for low-hazard residential devices such as irrigation | Notices go out 30 days before the due date |
| Horseshoe Bay, TX | On installation, then at least every five years | Commercial, multi-family and HOA or POA systems: annually |
| San Antonio Water System, TX | Annually | Residential reminders for lawn irrigation devices are sent quarterly |
| Ohio, state rule; Gahanna, OH | At least once every 12 months | Gahanna: a device tested in May is due by the last day of May the next year |
| O'Fallon, MO | Annually | Reports due June 1; $30 late fee for homes; reports not in by July 1 are subject to disconnection |
| Washington, state rule; Spokane, WA | On installation, repair, reinstallation, relocation or after an incident; then annually | Spokane: every year, "ideally before you turn on your irrigation system" |
| California, state policy | At least annually, plus after installation, repair, "depressurization for winterizing" or permanent relocation (for assemblies installed for the water system's cross-connection program) | Failed assemblies repaired or replaced within 30 days of notice |
| Minnesota, state plumbing code | On installation and at least annually | For non-RP testable devices, the rule covers installations made on or after Jan. 23, 2016; results due within 30 days |
| Salt Lake City, UT | "Tested annually or 10 days after installation" | Reports go to the city's cross-connection office |
Sources: each rule or utility's own page, listed below. The O'Fallon and Spokane pages are Internet Archive copies (May 13 and October 14, 2026).
The Minnesota date matters for older homes there: RPs "have had testing requirements for many years," but the duty for PVBs and other non-RP testable devices applies to installations made on or after January 23, 2016.
You still test a system you never turn on
Two utilities say plainly that the test does not lapse with the lawn. Spokane: "Even unused systems require annual testing because water sitting in the system can become contaminated." Gahanna's reason is that the system "is still physically connected to the public water supply." Both name the same way out: have the line to the irrigation system cut and capped. Gahanna inspects the cut and cap at no charge and then marks the system inactive. Spokane asks for photos of the capped line. If you reconnect later, Gahanna says you must tell the city, and annual testing starts again.
Spring start-up and the backflow test: which comes first
A spring start-up and a backflow test are two different jobs, and utilities treat them that way. Gahanna's FAQ explains the difference: "A spring startup service is performed on the irrigation system as whole to check for leaks, clogs, etc. A backflow test is specifically performed on the device itself to ensure that is working properly." The start-up date moves with the weather. The test date, Gahanna says, does not: "Testing the device once every 12 months after the previous test date is a firm deadline."
Example (Gahanna row of the table above): your device was last tested in May, and a warm spring means you want water in March. Gahanna's own advice is to have the start-up done in March and the backflow test in May, so your testing month stays the same every year.
Spokane instead suggests testing "ideally before you turn on your irrigation system." Either way, the tester has to be certified, and many utilities take results only from testers on their own list. Marin Water says that if a test is done by someone not on its list, it "cannot accept the test results." Gahanna notes the start-up technician may not be certified, so a second employee may test.
Example (California row): a sprinkler assembly in California is drained in November and refilled in April. The state handbook says a water system must ensure that all assemblies "installed for its Cross-Connection Control Program" are field tested "following installation, repair, depressurization for winterizing, or permanent relocation" (section 3.3.3(a)). The duty sits with the water system, so ask yours whether your sprinkler assembly is in its program and wants a test after a winter drain-down. If so, plan the test after the April refill.
A start-up order that works with all of these rules:
- Find the due date on your notice or last report. Texas' test form puts annual tests "no more than 12 months from the last test date," not by calendar year.
- Before turning the water back on, close the test cocks and ball valves you opened for winter. CSU says to open the ball valves slowly once the supply is on, because doing so "will prevent damage to the system that can be caused by water hammer."
- Look at the device and the pipes on either side. University of Georgia Extension notes that with home irrigation "you probably wouldn't know you had any pipe damage until you turned it on for the first spring watering."
- If the assembly cracked or leaks, it needs repair, and a repair triggers a test in Texas, Washington, California and Houston, among others.
- Book a tester from your utility's list for a date inside your window. Find your utility in the backflow tester directory.
- Keep a copy of the report. Gahanna says the tester submits a copy to the city, but keeping records "is your responsibility."
Winterizing a sprinkler backflow preventer
Sprinkler backflow devices sit at or above ground level, outside the soil that shelters buried pipe. CSU explains why freezing does so much damage: water contracts as it cools only until it reaches 39°F, then expands as it turns to ice, increasing "in volume by one-eleventh, so 11 cubic feet of water will form approximately 12 cubic feet of ice" (CSU Extension, Preparing Your Sprinkler System for Winter, reviewed August 2025). Salt Lake City's guide adds that "most sprinkling system piping is not below frost levels," and that water freezing in the backflow preventer or its ball valves "can cause internal damage or possible crack the device or valve." Even in Georgia, where only the top few inches of ground tend to freeze in most of the state, UGA Extension warns that "backflow prevention valves, are at ground level and could be in danger."
| Device | What the sources say to do for winter | Source |
|---|---|---|
| PVB | After the lines are blown out, work the ball valves and test cocks back and forth several times and leave them half open; ball valves left fully open or fully closed "tend to trap water, expand and cause damage." Salt Lake City: open the test cocks a quarter turn and set the shutoff valves at 45 degrees | CSU; Salt Lake City |
| RP | Drain both check zones separately: close the upstream shutoff, open test cocks 2 and 3 to drain the first zone, drain the line upstream, and for the second zone remove the check cap, spring and disc holder, then put them back. Leave the ball valves at about 45 degrees all winter | CSU |
| Any testable assembly fitted with unions | Optional: take it off, drain both sides, open the test cocks, set the valves a quarter turn, and store it indoors; Salt Lake City adds that "it may also be good to wrap it in a towel or old blanket" | Salt Lake City |
| AVB | Cleared with compressed air when its zone is blown out | CSU |
| Hose connection vacuum breaker | "Best removed, drained, and stored for the winter" | CSU |
| Texas and other mild-winter areas | Turn off the controller and the irrigation supply near the meter or backflow assembly, insulate exposed PVC, and drain above-ground parts such as backflow assemblies. "Most landscape irrigation systems in Texas are not designed for a blow out" | Texas A&M School of Irrigation |
Never blow compressed air through a PVB or RP. CSU: these devices "must never be blown out with compressed air. The rubber seals inside can easily melt from the heat of the air." Connect the compressor at a blowout fitting downstream of the assembly with the downstream ball valve closed. CSU puts the working air pressure at 40 to 80 psi, with 80 psi the maximum for rigid PVC pipe and 50 psi for flexible polyethylene, and its PlantTalk service says "preferably" have systems blown out by professionals.
Two rule questions follow from winterizing, and both are for your utility. First, whether California's winterizing trigger covers your assembly, as above. Second, if you take the assembly off for winter: Washington's rule lists "reinstallation" among the events after which the purveyor must ensure an inspection or test, but does not say whether a spring re-mount counts. Ask before you plan on removing it. Freeze damage is simpler: a cracked body or a split valve is a repair or a replacement, and both bring a new test.
Replacing, moving or removing the device
Replacing a backflow preventer usually means a permit. CSU says permits "normally are required" for sprinkler systems that need backflow devices, with the device type and location approved in plan review. Minnesota's plumbing code requires a permit before installation, installation by a licensed plumber, and notice to the public water supplier within 30 days (Minnesota DLI fact sheet). The backflow test report form included in Hastings' irrigation permit packet states that "a plumbing permit is required for the installation, removal or replacement of all backflow preventers."
A new or moved device gets a new test. Texas requires one on installation, repair, replacement or relocation; Washington on installation, repair, reinstallation or relocation; Houston on installation, repair and relocation. California adds that a water system must receive a passing test "before providing continuous service to a water user with a newly installed BPA" (section 3.3.3(d)). Deadlines are short: ten business days for a Texas irrigator to send results, 10 days after installation in Salt Lake City, and 30 days in Minnesota.
Moving a device can also end its grandfather status. Oregon lets older assemblies that are no longer on the approved list stay in service only if "the assemblies are not moved, the piping systems are not significantly remodeled or modified," they are maintained, and they match the hazard (OAR 333-061-0070(14)). Salt Lake City lets an existing double check stay on a lawn system if it was installed under the previous code and tested annually, but will not accept a new one. Horseshoe Bay lets older non-RP devices on commercial, multi-family and HOA systems "remain until they fail and must be replaced," and new installations on those systems must be an RP above ground. Spokane answers the grandfathering question for homes directly: "All properties must comply with current backflow prevention requirements, regardless of how long you've lived there."
The replacement itself has to be an approved model. Oregon's rule (USC FCCCHR approval or an equivalent laboratory the state approves) and Spokane's guidance both point to the USC FCCCHR list. The Foundation says assemblies on its list are "approved for a period of three years and this approval is subject to renewal," that the list names the shutoff valves that may be used as replacements, and that "the use of shutoff valves other than those listed invalidates the Foundation's approval" (USC FCCCHR, List of Approved Backflow Prevention Assemblies). Costs for repair, replacement and permits are in the cost guide.
If you remove a device for good, tell the utility so its records match the yard. Houston asks your plumber, engineer or testing company to send a Backflow Prevention Assembly Removal Form.
Wells, ponds and secondary water on the same system
A second water source changes the device. Texas requires an RP or air gap whenever "any additional water source" connects to an irrigation system that is also on the potable supply (30 TAC 344.51(c)). Salt Lake City specifies an RP where secondary water is available, and CSU says Colorado's dual systems, which carry irrigation and potable water through the same pipes, need an RP. A system fed only by ditch water and never connected to the potable supply needs no backflow device, according to CSU.
The reason is the same backpressure problem. One of the illustrated cases in EPA's manual is a house whose city-supplied plumbing is connected by a valve to a private well used for lawn sprinkling, and the well is polluted by sewage seeping from a cesspool. During low city pressure, "possibly when lawn sprinkling is at its peak," the well pump pushed well water into the city supply through an open or leaky valve. EPA's suggested correction: the connection between the well water and city water "should be broken." In the East Bay, EBMUD requires customers with private wells to test a backflow preventer every year, and its FAQ says the requirement holds even when the well serves only irrigation (EBMUD testers).
Property managers: many devices, different clocks
Rules can treat managed landscapes differently from the houses around them. Horseshoe Bay tests HOA and POA systems every year, and Washington lists irrigation with chemical addition at parks, golf courses and cemeteries as high hazard. Where the clock runs 12 months from each device's last test, as in Gahanna, devices tested at different times keep different due dates. Keep a list by serial number and location that matches the utility's records, and book by due date, not by season.
Next step
Find your water utility in the backflow tester directory and book a tester from its list inside your test window. Utility pages include Salt Lake City, whose winterizing sheet is quoted above; Round Rock, with its seven-year residential cycle; Houston; Columbus, which falls under Ohio's rules (the PVB exception for water-only lawn systems is one a water supplier may apply, so ask); and Marin Water in California. If you are adding an injector, a pump or a well connection, ask the utility which device it requires first, then plan the work.
Questions people ask
Does a sprinkler system's backflow preventer need testing every year?
Should the backflow test happen before or after spring start-up?
Do I have to test the backflow device if I never use my sprinklers?
Which backflow preventer does a lawn sprinkler system need?
Do I need an RP if I inject fertilizer through my sprinkler system?
How do I winterize a backflow preventer?
Do I need a new backflow test after replacing or moving the device?
Can my irrigation company test my backflow preventer?
- Colorado State University Extension, Home Sprinkler Systems: Backflow Prevention Devices (published April 2003, reviewed August 2025) (accessed 2026-11-04)
- Colorado State University Extension, Home Sprinkler Systems: Preparing Your Sprinkler System for Winter (published October 2014, reviewed August 2025) (accessed 2026-11-04)
- Colorado State University Extension, PlantTalk Colorado 2205: Winterizing Sprinkler Systems (accessed 2026-11-04)
- Salt Lake City Department of Public Utilities, Winterizing Your Lawn Sprinkler System and Backflow Preventer (accessed 2026-11-04)
- Salt Lake City Public Utilities, Cross Connection Control and Backflow Prevention (accessed 2026-11-04)
- 30 Texas Administrative Code §344.50, Backflow Prevention Methods (eff. 7/26/2020; via Cornell Legal Information Institute) (accessed 2026-11-04)
- 30 Texas Administrative Code §344.51, Specific Conditions and Cross-Connection Control (eff. 7/26/2020; via Cornell LII) (accessed 2026-11-04)
- 30 Texas Administrative Code §344.52, Installation of Backflow Prevention Assembly (eff. 7/26/2020; via Cornell LII) (accessed 2026-11-04)
- 30 Texas Administrative Code §344.1, Definitions (eff. 7/26/2020; via Cornell LII) (accessed 2026-11-04)
- Texas Commission on Environmental Quality, Form TCEQ-20700 Test and Maintenance Report instructions (Revision 04-04-2019) (accessed 2026-11-04)
- Washington Administrative Code 246-290-490, Cross-connection control (WSR 21-23-097, effective 1/1/22) (accessed 2026-11-04)
- California State Water Resources Control Board, Cross-Connection Control Policy Handbook (adopted December 19, 2023; amended April 21, 2026) (accessed 2026-11-04)
- Ohio Administrative Code 3745-95-05, Type of protection required (effective 10/10/2022; via Cornell LII) (accessed 2026-11-04)
- Ohio Administrative Code 3745-95-05, official text on codes.ohio.gov (Internet Archive capture, January 17, 2026; page says last updated June 26, 2025, effective October 10, 2022) (accessed 2026-11-04)
- Ohio Administrative Code 3745-95-06, Backflow preventers (effective 10/10/2022; via Cornell LII) (accessed 2026-11-04)
- Oregon Administrative Rules 333-061-0070, Cross Connection Control Requirements (via Cornell LII) (accessed 2026-11-04)
- Minnesota Department of Labor and Industry, Fact Sheet: Backflow Devices, 2020 Minnesota Plumbing Code (accessed 2026-11-04)
- City of Hastings, Minnesota, Department of Building Safety, Irrigation permit packet (accessed 2026-11-04)
- City of Gahanna, Ohio, FAQs: Residential Irrigation System (accessed 2026-11-04)
- City of Spokane, Cross-Connection Control and Backflow Prevention Program (Internet Archive capture of the official page, October 14, 2026; live page returned 403) (accessed 2026-11-04)
- City of O'Fallon, Missouri, Backflow Testing for Irrigation Systems (Internet Archive capture of the official page, May 13, 2026; live page did not connect) (accessed 2026-11-04)
- City of Horseshoe Bay, Texas, Irrigation Backflow Testing Program (accessed 2026-11-04)
- City of Round Rock Utilities and Environmental Services, Backflow Prevention (accessed 2026-11-04)
- San Antonio Water System, Annual Testing of Backflow Prevention Assemblies (accessed 2026-11-04)
- Houston Public Works, Cross Connection Control Program (accessed 2026-11-04)
- East Bay Municipal Utility District (EBMUD), Backflow prevention (accessed 2026-11-04)
- Marin Water, Backflow prevention (accessed 2026-11-04)
- Texas A&M AgriLife, School of Irrigation, Winterization (accessed 2026-11-04)
- University of Georgia Extension, Fannin-Gilmer County, Winterizing Outdoor Pipes and Sprinklers (December 17, 2020) (accessed 2026-11-04)
- U.S. EPA, Cross-Connection Control Manual (EPA 816-R-03-002, February 2003) (accessed 2026-11-04)
- USC Foundation for Cross-Connection Control and Hydraulic Research, Prevalence of Cross-Connections in Household Plumbing (page) (accessed 2026-11-04)
- USC Foundation for Cross-Connection Control and Hydraulic Research, Prevalence of Cross-Connections in Household Plumbing Systems (report dated February 3, 2004) (accessed 2026-11-04)
- USC Foundation for Cross-Connection Control and Hydraulic Research, List of Approved Backflow Prevention Assemblies (accessed 2026-11-04)